Fan working strategy¶
EC-A1684JD4 fans work in 4 levels:
Main control current temperature | Fan working level |
---|---|
≥ 33℃ | 1 |
≥ 45℃ | 2 |
≥ 55℃ | 3 |
≥ 60℃ | 4 |
The higher the working level of the fan, the faster the speed. If the current temperature of the main controller is lower than 33°C, the fan is turned off by default.
Users can view the current working temperature of the main controller by executing the following command:
cat /sys/class/thermal/thermal_zone1/temp
For example the following is 45.5°C:
linaro@bm1684:~$ cat /sys/class/thermal/thermal_zone1/temp
45500
In addition, the user can also manually turn on the fan by himself (write 0-4, 0 is off, 4 is the maximum level):
sudo -i
echo 4 > /sys/class/thermal/cooling_device0/cur_state